Complete guide

96-Well Plate

The 96-well plate is the most widely used microplate in the laboratory. This guide covers everything the format involves: its layout and dimensions, well volume, bottom shapes, colours, materials, applications and the instruments it works with.

96-well plate, 8 rows by 12 columns123456789101112ABCDEFGH
A 96-well plate: 8 rows (A–H) × 12 columns (1–12), 9 mm well pitch.

Quick answer

A 96-well plate is a flat, rectangular microplate with 96 wells in an 8 × 12 grid (rows A–H, columns 1–12). It follows the SBS/ANSI standard footprint of 127.76 × 85.48 mm, holds about 100–200 µL per well, and lets a lab run up to 96 samples in parallel for assays such as ELISA, qPCR and cell culture.

Wells
968 × 12
Coordinates
A1–H12
Footprint
127.8 × 85.5mm
Well pitch
9.0mm
Working volume
100–200µL
Material
Polystyrene
Key takeaways
  • 96 wells in an 8 × 12 grid, addressed A1–H12.
  • Standard SBS/ANSI footprint makes every brand instrument-compatible.
  • Choose bottom shape (flat/round/V), colour (clear/black/white) and material to match your assay.
  • Working volume ~100–200 µL; deep-well versions hold 1–2 mL.

What is a 96-well plate?

A 96-well plate is a rigid tray moulded with 96 small wells in eight rows and twelve columns. Each well behaves like an independent miniature test tube, so one plate can hold 96 separate samples, reactions or conditions that are pipetted, incubated and read together. It is the single most common vessel in analytical and screening laboratories.

The plate is also called a microplate, microtiter plate, microwell plate or multiwell plate: the terms are interchangeable. “Microtiter” began as a trade name in the 1950s and stuck. Wells are addressed by row letter (A–H) and column number (1–12), giving unique coordinates such as C7 that anchor every plate map.

Purpose & benefits

Three properties make the 96-well plate indispensable:

  • Parallelism. Ninety-six wells mean 96 samples, a full standard curve, or many replicates processed at once, with the same reagents, timing and conditions across all wells.
  • Standardization. A fixed footprint lets the plate drop into readers, washers, shakers and robots from any manufacturer.
  • Miniaturization. Microlitre volumes cut reagent cost and sample use versus test tubes, while remaining easy to handle by multichannel pipette.

The standard format

The 96-well layout is defined by the ANSI/SLAS microplate standards (formerly SBS standards). They fix the outer footprint and well spacing so labware is interchangeable across the industry. The 96-well is the reference format from which the 384- and 1536-well plates are derived by halving the pitch.

Dimensions & size

Key measurements of a standard (non-deep) 96-well plate:

Footprint
127.76 × 85.48 mm (length × width)
Height
≈ 14.4 mm (varies by type and lid)
Well pitch
9.0 mm, centre-to-centre
Well diameter
≈ 6.4 mm (flat bottom, top)
Well depth
≈ 10.9 mm
A1 position
14.38 mm from left, 11.24 mm from top
Lid
Adds ~1.5–2.5 mm to plate height; same footprint

For plate height by type, the flat-bottom well profile and a 96-vs-384 comparison, see the dedicated 96-well plate dimensions page.

Well volume: how much a well holds

A standard flat-bottom well has a working volume of 100–200 µL and a maximum of about 360 µL. Working volume is the amount used in practice, enough to cover the well base and give a clean optical path, while the maximum is the physical brim capacity, rarely filled to avoid spillage and cross-contamination. A deep-well 96 plate holds far more, typically 1–2 mL per well, for storage and extraction. Compare all formats on the surface area & volume chart.

Well-bottom shapes

The shape of the well base is chosen to match the assay and readout:

Flat bottom (F)

Optics · adherent culture

A flat optical path for absorbance and imaging, and a flat surface for adherent cells to attach. The default for most assays.

Round / U-bottom (U)

Suspension · washing · pelleting

A curved base that gently pools cells and suspensions at the centre, used for immunology, bead assays, ELISA wash steps, and collecting non-adherent cells into a pellet for resuspension. (“Round bottom” and “U-bottom” are the same U geometry.)

V-bottom (V)

Maximum recovery

Concentrates small volumes and pellets into a point, so nearly all sample can be recovered.

Colour & optical options

Plate colour controls stray light and is matched to the detection method:

  • Clear: for absorbance (colorimetric) reads and brightfield imaging.
  • Black: absorbs light to minimise background and cross-talk in fluorescence.
  • White: reflects light to maximise signal in luminescence assays.
  • Black or white with a clear bottom: combines low-background walls with an optical base for bottom-reading and live-cell imaging.

Common 96-well variants

Beyond bottom shape and colour, the 96-well format ships in several purpose-built variants:

  • Strip-well plates: 8- or 12-well breakable strips in a frame, the standard choice for ELISA when you want to run only part of a plate.
  • Half-area plates: narrower wells that halve the volume (~25–100 µL) to save reagent in absorbance and fluorescence assays.
  • PCR plates (skirted, semi-skirted, non-skirted): thin-wall 96-well plates that fit a thermal cycler block; the skirt style is chosen for the instrument and sealing method.
  • Ultra-low-attachment plates: a coating that prevents adhesion, used to grow spheroids and organoids in suspension.

Materials

Most plates are polystyrene: transparent, inexpensive and readily tissue-culture (TC) treated so adherent cells attach and spread. Polypropylene plates resist solvents (e.g. DMSO) and freeze–thaw, making them the choice for compound storage and PCR. For UV measurements, ordinary polystyrene absorbs UV, so UV-transparent plastics (such as cyclic-olefin) or quartz plates are used instead. Plates are supplied sterile (for cell culture) or non-sterile (for biochemistry).

Applications

The format underpins most parallel laboratory methods:

ApplicationWhat the plate does
ELISAImmobilised antibodies capture a target; colour/luminescent signal quantifies it across samples.
qPCR96 parallel real-time amplification reactions in a thermocycler block.
Absorbance assaysBCA/Bradford protein, MTT viability, growth (OD) read by a plate reader.
Fluorescence / luminescenceReporter, viability and binding assays in black or white plates.
Cell culture & imagingAdherent cells in TC-treated wells for viability, cytotoxicity and high-content imaging.
Bacterial cultureGrowth curves and MIC assays via OD600 across many conditions.
High-throughput screeningCompound libraries tested against a target with liquid handlers.

See what well plates are used for for a fuller breakdown.

Instruments & accessories

A 96-well plate is read and handled by a microplate reader (or plate spectrophotometer), and processed with plate washers, shakers/incubators, centrifuges and robotic liquid handlers, all built to the standard footprint. Common accessories include lids, adhesive and heat-seal films for storage and PCR, and sealing mats.

Common brands

Widely used 96-well plates include Corning (and its Costar line), Greiner Bio-One, Thermo Fisher (Nunc), Eppendorf, Sarstedt and Azenta. All share the standard footprint, so the templates and tools on this site apply regardless of brand.

How to choose a 96-well plate

Selection rule

Match bottom shape to handling (flat = optics/adherent, round/V = collection/recovery), colour to readout (clear = absorbance, black = fluorescence, white = luminescence), and material to chemistry (polystyrene = optics/culture, polypropylene = storage/PCR, UV-transparent = UV reads).

How to seed cells in a 96-well plate

For adherent cell assays, a typical seeding density is roughly 1–5 × 10⁴ cells per well in 100–200 µL of medium, adjusted for cell type, growth rate and assay length so wells reach the target confluency at read-out. Dispense a master cell suspension with a multichannel pipette, keep the plate level, and leave outer wells as medium-only blanks if edge effects are a concern.

Cost

Standard 96-well plates are inexpensive, typically a few dollars each, less in bulk. Specialty plates (TC-treated, black/white, sterile, low-binding or UV-transparent) cost more. The templates and plate designer on this site are free.

Frequently asked questions

What is a 96-well plate?

A 96-well plate is a flat, rectangular microplate containing 96 small wells arranged in an 8 × 12 grid (rows A–H, columns 1–12). Each well acts as an independent miniature test tube, letting a lab run up to 96 samples or reactions in parallel and read them with standard instruments.

What is a 96-well plate called?

It is also called a microplate, microtiter plate, microwell plate or multiwell plate. 'Microtiter' originated as a trade name; all four terms refer to the same standardized 96-well labware.

What material is a 96-well plate made of?

Most are moulded from polystyrene, which is optically clear and can be tissue-culture treated for cell attachment. Polypropylene versions are used for storage and PCR because they resist chemicals and low temperatures. Special UV-transparent plastics (e.g. cyclic olefin) are used for UV measurements, since ordinary polystyrene absorbs UV light.

What shape is the bottom of a 96-well plate?

Wells come in flat (F), round/U (U) and V-shaped (V) bottoms. Flat bottoms suit optical reads and adherent cell culture; round/U bottoms gently collect cells and suspensions; V bottoms concentrate small pellets for maximum recovery.

How much can a well in a 96-well plate hold?

A standard flat-bottom 96-well plate holds a working volume of about 100–200 µL per well and a maximum of roughly 360 µL. Deep-well 96 plates hold much more, about 1–2 mL per well.

What size is a 96-well plate?

Every standard microplate shares the SBS/ANSI footprint of 127.76 × 85.48 mm, about 14.4 mm tall. Wells sit on a 9 mm pitch and are roughly 6.4 mm across.

What is a 96-well plate used for?

It is used for parallel assays and screening: ELISA, qPCR, absorbance/fluorescence/luminescence measurements, cell-based assays, bacterial growth curves and high-throughput drug screening.

What is the standard 96-well plate format?

The standard is defined by the ANSI/SLAS microplate standards: a fixed 127.76 × 85.48 mm footprint with 96 wells on a 9 mm pitch, so plates and instruments from any manufacturer are interchangeable.

Sources & standards
  1. ANSI/SLAS 1-2004, Microplates: Footprint Dimensions
  2. ANSI/SLAS 4-2004, Microplates: Well Positions
  3. Manufacturer specification sheets (Corning, Greiner Bio-One, Thermo Scientific Nunc). Verify exact values per product.