Free template · 6 × 8 · A–F · 1–8
48-Well Plate Template
Free 48-well plate template (6 × 8 grid, A–F, 1–8) in Word, Excel, PDF, PPT, PNG and SVG: a higher-density format for optimization and small assays.
Quick answer
A 48-well plate template is a blank 6 × 8 grid (rows A–F, columns 1–8). At about 1.1 cm² and 0.2–0.5 mL per well, it packs more conditions onto a standard footprint than a 24-well. Free in Word, Excel, PDF, PowerPoint, PNG and SVG.
Download the 48-well plate template
Editable Word and Excel, print-ready PDF, PowerPoint, and high-resolution PNG and vector SVG, all on the standard 6 × 8 grid with labelled rows and columns.

Design your 48-well layout online
Assign samples and controls, colour-code groups, and export a plate map or CSV.
- 48 wells in a 6 × 8 grid (A–F, 1–8).
- ≈ 1.1 cm² per well · 0.2–0.5 mL working volume.
- Standard SBS/ANSI footprint that fits any plate reader or handler.
- Free in Word, Excel, PDF, PowerPoint, PNG and SVG.
About the 48-well plate
The 48-well plate packs more conditions onto a standard footprint than the 24-well while keeping wells large enough (~1.1 cm²) for adherent growth. Its 6 × 8 arrangement is handy for optimization matrices and microbial growth curves.
Wells are addressed A1–F8. It is a practical bridge between mid-scale culture plates and the true high-throughput 96- and 384-well formats.
48-well plate dimensions & volume
| Specification | Nominal value |
|---|---|
| Wells / layout | 48 (6 × 8) |
| Row / column labels | A–F / 1–8 |
| Plate footprint | 127.76 × 85.48 mm |
| Well spacing (pitch) | 13 mm |
| Well diameter | ≈ 11.1 mm |
| Growth area / well | ≈ 1.1 cm² |
| Working volume | 0.2–0.5 mL |
| Max volume | 1.6 mL |
Nominal values for a standard flat-bottom plate; exact figures vary by manufacturer and plate type. See how the 48-well growth area is derived.
A 48-well roughly halves the throughput of a 96-well but doubles per-well area and volume, which helps when 96-well wells are too small for your cells or readout. See the 96-well plate template or the full dimensions guide.
Working volume & cell seeding
48-well wells use roughly 0.2–0.5 mL of medium, seeded on the order of a few × 10⁴ cells per well. The higher density suits optimization matrices and microbial growth curves where you want many conditions but still adequate cells per well.
Example layout: bacterial growth curve
A 48-well plate reads well in a shaking plate reader and still holds enough broth for a real growth curve. Six isolates go down the rows, seven conditions run across the columns, and the last column stays sterile so drift in the reader is visible.
- Isolates across seven conditions
- Sterile broth blank
- Rows A to F are six isolates or strains, one per row.
- Columns 1 to 7 hold the conditions, for example a carbon source series or a sub-inhibitory antibiotic range.
- Column 8 is broth with no inoculum. Any rise there means contamination, not growth.
- Read optical density at 600 nm on a fixed interval, and keep the lid on with condensation rings facing down to limit evaporation over a long run.
Rebuild this layout in the plate designer and export it as a PNG or CSV, or see more worked layouts in the template library.
Stepping up or down a format
| Format | Wells | Area/well | Working volume |
|---|---|---|---|
| 24-well | 24 | 1.9 cm² | 0.5–1.0 mL |
| 48-well (this page) | 48 | 1.1 cm² | 0.2–0.5 mL |
| 96-well | 96 | 0.32 cm² | 100–200 µL |
- Step down a format when each condition needs imaging or more than a millilitre of medium, which the 24-well handles better.
- Step up a format when the run grows past 48 conditions and 100 to 200 microlitres per well is enough, which is standard 96-well territory.
- Work through the full decision in choosing the right well plate template.
Common uses
- Condition optimization. Test many media/treatment combinations with adequate cells per well.
- Bacterial & yeast growth. Growth curves with enough volume for reliable OD readings.
- Small biochemical assays. More replicates than a 24-well in the same footprint.
Frequently asked questions
What is a 48-well plate used for?
The 48-well plate suits condition optimization, bacterial and yeast growth curves, and small biochemical assays. It packs more conditions onto a standard footprint than a 24-well while keeping wells large enough for adherent growth.
How many wells does a 48-well plate have and what is the layout?
48 wells in a 6 × 8 grid: rows A–F and columns 1–8, addressed A1 through F8.
What is the working volume of a 48-well plate?
Roughly 0.2–0.5 mL of medium per well, with about 1.1 cm² of growth area. The maximum is near 1.6 mL.
How many cells should I seed in a 48-well plate?
Adherent cells are commonly seeded on the order of a few × 10⁴ per well, scaled by growth area from your usual format.
What are the dimensions of a 48-well plate?
48 wells in a 6 × 8 grid on the standard 127.76 × 85.48 mm footprint, with wells about 11.1 mm across on a 13 mm pitch.
Is the 48-well template free to download?
Yes. Word, Excel, PDF, PowerPoint, PNG and SVG are all free for any lab use.
Why use a 48-well plate for bacterial growth curves?
It holds enough broth per well for a curve that is not dominated by evaporation, while still fitting six strains and a full condition series on one plate. Wells take roughly 0.5 to 1 mL, which is several times a 96-well, and the plate reads in any shaking reader at 600 nm.
How do I limit evaporation during a long 48-well run?
Keep the lid on, seal with a gas-permeable membrane for aerobic cultures, and fill the outer wells with medium if you are not using them. Reserve at least one column of sterile broth so you can tell contamination and reader drift apart from real growth.
Is a 48-well plate read by standard plate readers?
Yes. The footprint is standard, so absorbance, fluorescence and luminescence readers all accept it, but the plate definition must match. Selecting a 96-well definition for a 48-well plate points the optics between wells.